Interface number changed
Modified on 2025-06-10 12:06:35 +0200
Attention: This article is a record of a conversation with the Paessler support team. The information in this conversation is not updated to preserve the historical record. As a result, some of the information or recommendations in this conversation might be out of date.
Important: We no longer maintain this article. The information might be out of date.
Hi,
some days ago I've involuntary disabled one of the two network interface on my server.
Then I turned it on again but it looks like the interface has change its OID or interface number and the relative sensor reports an error.
Of course I can create a new correct sensor but I would lose all historic data.
How can I solve this problem?
Thanks in advance for help
cotus
Article Comments
Disclaimer:
The information in the Paessler Knowledge Base comes without warranty of any kind. Use at your own risk. Before applying any instructions please exercise proper system administrator housekeeping. You must make sure that a proper backup of all your data is available.
Dear Cotus,
please see How can I move the historic data of one sensor to another ?. The article will show one "official supported" option and another one which involves editing the configuration file, which would not be supported.
Best Regards.
Nov, 2010 - Permalink