PRTG is returning an OID error Please enter a valid OID value (e.g. 1.3.6.1.2.1.1.3.0) when I type input OID value - 1.3.6.14.1.2603.5.4.2.1.1.23.0.48 I am trying to graph Pipes configured in the Allot NetEnforcer.
PRTG version: 13.1.1.1182
Modified on 2025-06-10 14:29:15 +0200
PRTG is returning an OID error Please enter a valid OID value (e.g. 1.3.6.1.2.1.1.3.0) when I type input OID value - 1.3.6.14.1.2603.5.4.2.1.1.23.0.48 I am trying to graph Pipes configured in the Allot NetEnforcer.
PRTG version: 13.1.1.1182
Currently PRTG's Custom SNMP and SNMP Trap Receiver sensors accept only OIDs which comply to RFC standards.
However, as of PRTG version 13.2 [Stable] OID handling will be less restrict, plus there will be an option to disable the RFC check altogether, so you can enter any OID value:
Improved [Sensors]: Added support for non-compliant OIDs for sensor types: SNMP Custom, SNMP Custom String, and SNMP Trap Receiver. New feature: In order to enter an OID into the "OID Value" field that does not begin with 1.0., 1.1., 1.2., or 1.3., add the string norfccheck: at the beginning of your OID.
A release of this version is planned for next week.
Feb, 2013 - Permalink