Hello,
I cannot use sensor "SNMP NetApp I/O": No such object (SNMP error # 222)
But e.g. "SNMP NetApp System Health" works fine. I use snmp v2c.
Article Comments
Dear Erhard,
there are no values:
----------------------- New Test ----------------------- Paessler SNMP Tester 5.2.3 Computername: Interface: () 29.04.2016 07:53:56 (28 ms) : Device: 29.04.2016 07:53:56 (44 ms) : SNMP V2c 29.04.2016 07:53:56 (58 ms) : Walk 1.3.6.1.4.1.789.1.2.2
----------------------- New Test ----------------------- Paessler SNMP Tester 5.2.3 Computername: Interface: () 29.04.2016 07:54:49 (27 ms) : Device: 29.04.2016 07:54:49 (40 ms) : SNMP V2c 29.04.2016 07:54:49 (52 ms) : Walk 1.3.6.1.4.1.789.1.17
( 1.3.6.1.4.1.789.1.2 and 1.3.6.1.4.1.789.1 delivers values )
Best regards Michael
Apr, 2016 - Permalink
Hi Michael,
Ok, so that explains the sensor message. Sure, the device delivers a lot of values when walking over 1.3.6.1.4.1.789.1.2 and 1.3.6.1.4.1.789.1, but it does not provide counters for those OIDs relevant for I/O data. Here you find an overview of the OID structure and all counters.
It may be a configuration issue, please contact NetApp for further assistance on why you don't get data for these "sub-OIDs".
Kind regards.
Apr, 2016 - Permalink
Hello Michael,
Please use our SNMP Tester, configure it to point to the device in question, select option "Walk" on each of the following OIDs:
These are the base OIDs the sensor expects to get data from. What results do you get when scanning for each OID?
Kind regards.
Apr, 2016 - Permalink