I am using Paessler Importer v3.4.7 and keep getting an this error "Something went wrong. Please check if all needed include/import files are in the stdmib or working path."

I have checked and verified that SNMPv2-SMI, SNMPv2-TC, SNMPv2-CONF, RFC1155-SMI are all in the /stdmib folder.

Any help is appreciated.... Here is the Mib file...

WNIP-BLADE-MIB DEFINITIONS ::= BEGIN

IMPORTS
    MODULE-IDENTITY, 
    OBJECT-TYPE, 
    NOTIFICATION-TYPE,
    mib-2,
    Integer32, 
    Counter32, 
    Gauge32, 
    TimeTicks  
        FROM SNMPv2-SMI

    TEXTUAL-CONVENTION, 
    DisplayString,
    TruthValue, 
    DateAndTime, 
    AutonomousType   
        FROM SNMPv2-TC

    OBJECT-GROUP, 
    NOTIFICATION-GROUP, 
    MODULE-COMPLIANCE
        FROM SNMPv2-CONF

    enterprises
        FROM RFC1155-SMI;


-- 1.3.6.1.4.1.41260
WheatMibModule MODULE-IDENTITY
    LAST-UPDATED "201302050000Z"    -- 5 Feb 2013
    ORGANIZATION "Wheatstone Corporation"
    CONTACT-INFO
        "Wheatstone Corporation
        Postal: Wheatstone Corporation
                600 Industrial Dr.
                New Bern, NC 28562 USA
                USA
        Phone:  252-638-7000
        Fax:    585-637-1285
        Email:  info@wheatstone.com"
        
    DESCRIPTION
        "This MIB is for use in managing wheatstone systems."
    REVISION     "201302050000Z"
    DESCRIPTION
            "Second draft"
    ::= { enterprises 41260 }

-- 1.3.6.1.4.1.41260.100
wheatstone OBJECT IDENTIFIER ::= { WheatMibModule 100 }

-- 1.3.6.1.4.1.41260.100.1
blade             OBJECT IDENTIFIER ::= { wheatstone 1 }

-- 1.3.6.1.4.1.41260.100.1.1
bladeStatusEntry  OBJECT IDENTIFIER ::= { blade 1 }

-- 1.3.6.1.4.1.41260.100.1.2 
bladeTraps        OBJECT IDENTIFIER ::= { blade 3 }

-- 1.3.6.1.4.1.41260.100.1.3.0
bladeTraps0       OBJECT IDENTIFIER ::= { bladeTraps 0 }

-- 1.3.6.1.4.1.41260.100.1.3.1
bladeTrapData     OBJECT IDENTIFIER ::= { bladeTraps 1 }

-- 1.3.6.1.4.1.41260.100.1.1.1
bladeId OBJECT-TYPE
    SYNTAX        Integer32
    MAX-ACCESS    read-only
    STATUS        current
    DESCRIPTION   "Blade Identifier."
    ::= { bladeStatusEntry 1 }

-- 1.3.6.1.4.1.41260.100.1.1.2
masterBladeId OBJECT-TYPE
    SYNTAX        Integer32
    MAX-ACCESS    read-only
    STATUS        current
    DESCRIPTION   "Master Blade ID."
    ::= { bladeStatusEntry 2 }

-- 1.3.6.1.4.1.41260.100.1.1.3
cmasterBladeId OBJECT-TYPE
    SYNTAX        Integer32
    MAX-ACCESS    read-only
    STATUS        current
    DESCRIPTION   "Clock Master Blade ID."
    ::= { bladeStatusEntry 3 }

-- 1.3.6.1.4.1.41260.100.1.1.4
bladeName OBJECT-TYPE
    SYNTAX        DisplayString (SIZE (0..100))
    MAX-ACCESS    read-only
    STATUS        current
    DESCRIPTION   "Blade Name."
    ::= { bladeStatusEntry 4 }

-- 1.3.6.1.4.1.41260.100.1.3.1.1
bladeTrapBladeId OBJECT-TYPE
    SYNTAX      Integer32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION   "Blade Id"
    ::= { bladeTrapData 1 }

-- 1.3.6.1.4.1.41260.100.1.3.1.2
bladeTrapBladeName OBJECT-TYPE
    SYNTAX      DisplayString (SIZE (0..100))
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION "Blade Name"
    ::= { bladeTrapData 2 }

-- 1.3.6.1.4.1.41260.100.1.3.1.3
bladeTrapSignalName OBJECT-TYPE
    SYNTAX      DisplayString (SIZE (0..100))
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION "Signal Name"
    ::= { bladeTrapData 3 }

-- 1.3.6.1.4.1.41260.100.1.3.1.4
bladeTrapSignalLocation OBJECT-TYPE
    SYNTAX      DisplayString (SIZE (0..100))
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION "Signal Location"
    ::= { bladeTrapData 4 }

-- 1.3.6.1.4.1.41260.100.1.3.1.5
bladeTrapSignalId OBJECT-TYPE
    SYNTAX      Integer32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION "The signal id."
    ::= { bladeTrapData 5 }

-- 1.3.6.1.4.1.41260.100.1.3.1.6
silenceDetectAudioState OBJECT-TYPE
    SYNTAX      DisplayString (SIZE (0..100))
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION "Silence Detector Audio State"
    ::= { bladeTrapData 6 }

-- 1.3.6.1.4.1.41260.100.1.3.1.7
silenceDetectSwitchState OBJECT-TYPE
    SYNTAX      DisplayString (SIZE (0..100))
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION "Silence Detector Switched State"
    ::= { bladeTrapData 7 }

-- 1.3.6.1.4.1.41260.100.1.3.1.8
bladeError OBJECT-TYPE
    SYNTAX      DisplayString (SIZE (0..100))
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION "Error Message"
    ::= { bladeTrapData 8 }

-- 1.3.6.1.4.1.41260.100.1.3.0.1
SilenceDetectAudioAlarm NOTIFICATION-TYPE
    OBJECTS {
        bladeTrapBladeId,
        bladeTrapBladeName,
        bladeTrapSignalName,
        bladeTrapSignalLocation,
        bladeTrapSignalId,
        silenceDetectAudioState
        
    }
    STATUS current
    DESCRIPTION
        "A SilenceDetectAudioAlarm trap signifies that a blade destination has detected silence or audio has resumed."
    ::= { bladeTraps0 1 }

-- 1.3.6.1.4.1.41260.100.1.3.0.2
SilenceDetectSwitched NOTIFICATION-TYPE
    OBJECTS {
        bladeTrapBladeId,
        bladeTrapBladeName,
        bladeTrapSignalName,
        bladeTrapSignalLocation,
        bladeTrapSignalId,
        silenceDetectAudioState
    }
    STATUS current
    DESCRIPTION
        "A SilenceDetectSwitched trap signifies that a blade destination has been switched to primary or secondary."
    ::= { bladeTraps0 2 }

-- 1.3.6.1.4.1.41260.100.1.3.0.3
bladeSoftwareFault NOTIFICATION-TYPE
    OBJECTS {
        bladeTrapBladeId,
        bladeTrapBladeName,
        bladeError
    }
    STATUS current
    DESCRIPTION
        "A bladeSoftwareFault trap signifies the blade has encountered a fatal software failure."
    ::= { bladeTraps0 3 }

-- 1.3.6.1.4.1.41260.100.1.3.0.4
bladeCriticalError NOTIFICATION-TYPE
    OBJECTS {
        bladeTrapBladeId,
        bladeTrapBladeName,
        bladeError
    }
    STATUS current
    DESCRIPTION
        "A bladeCriticalError trap signifies the blade has encountered a critical problem that may hinder operation."
    ::= { bladeTraps0 4 }

END

Article Comments

We were able to import all elements compatible with SNMP Library sensors. Please forward us an email to support@paessler.com refering to this thread and we will forward you the imported OIDLIB file.


Oct, 2013 - Permalink