I want to monitor NetApp via SNMP. However, I get an error message saying
No Such Name (SNMP error # 2)
What can I do?
Article Comments
Monitoring my NetApp with the provided SNMP Sensors i got the problem that only the SNMP I/O Sensor reports a failure: No such object (SNMP-Fehler # 222). All other SNMP Sensors are working right with the v2c Version.
Jan, 2016 - Permalink
When you use our SNMP tester and do a walk on the OID 1.3.6.1.4.1.789.1, what results do you get? Can you post the log files from the tester?
Jan, 2016 - Permalink
This article applies to PRTG Network Monitor 12.3 or later
Use SNMP version 2c For NetApp Monitoring
To our experience, a NetApp does not provide all counters via SNMP v1. This results in the error message quoted above.
In order to receive all counters in your NetApp sensors, please change the SNMP version from v1 to v2c. You can do this in the PRTG web interface in the Settings tab of the device which represents your NetApp.
Aug, 2012 - Permalink