Is it possible to change HTTP XML/REST Value Sensor timeout from default 15 seconds to 30 or 45 seconds?
HTTP XML/REST Value Sensor timeout settings.
Modified on 2025-06-10 22:46:43 +0200
Disclaimer:
The information in the Paessler Knowledge Base comes without warranty of any kind. Use at your own risk. Before applying any instructions please exercise proper system administrator housekeeping. You must make sure that a proper backup of all your data is available.
The information in the Paessler Knowledge Base comes without warranty of any kind. Use at your own risk. Before applying any instructions please exercise proper system administrator housekeeping. You must make sure that a proper backup of all your data is available.
Hi,
by default thsi is not possible. However, you might copy the sensor exe (<PRTG INSTALL DIRECTORY>\Sensor System\XMLValue.exe) to the folder <PRTG INSTALL DIRECTORY>\Custom Sensors\EXEXML and run the same as EXE Script Advanced Sensor (doubleclick the sensor exe for a list of parameters) where you can pas the timeout as parameter.
Best regards